LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

The impact of body mass index on the risk of high spinal block in parturients undergoing cesarean delivery: a retrospective cohort study

Photo from wikipedia

PurposeTo investigate the hypothesis that the risk of high spinal block is not increased in obese parturients undergoing cesarean delivery compared to non-obese parturients.MethodsThis is a retrospective study at an… Click to show full abstract

PurposeTo investigate the hypothesis that the risk of high spinal block is not increased in obese parturients undergoing cesarean delivery compared to non-obese parturients.MethodsThis is a retrospective study at an academic center. We searched the perioperative database for women who underwent cesarean delivery under spinal or combined spinal epidural anesthesia with hyperbaric bupivacaine ≥10.5 mg. A body mass index (BMI) ≥30 kg/m2 was defined as obese. We categorized obesity into: obesity class I (BMI = 30–34.9 kg/m2), obesity class II (BMI = 35–39.9 kg/m2), obesity class III (BMI = 40–49.9 kg/m2), and super obese (BMI ≥50 kg/m2). The primary outcome was high spinal block defined as need to convert to general anesthesia within 20 min of spinal placement as a result of altered mental status, weakness, or respiratory distress resulting from the high block, or a recorded block height ≥T1.ResultsThe analysis included 5015 women. High spinal blocks occurred in 29 patients (0.6%). The risk of high spinal was significantly different according to BMI (p = 0.025). In a multivariate model, BMI (p = 0.008) and cesarean delivery priority (p = 0.009) were associated with high blocks. BMI ≥50 kg/m2 was associated with greater odds of high block compared to BMI <30 kg/m2 [odds ratio (95% confidence interval): 6.3 (2.2, 18.5)]. Scheduled cesarean delivery was also associated with greater odds of high block compared with unscheduled delivery.ConclusionsAt standard spinal doses of hyperbaric bupivacaine used in our practice (≥10.5 mg), there were greater odds of high block in those with BMI ≥50 kg/m2.

Keywords: block; bmi; delivery; cesarean delivery; high spinal; risk high

Journal Title: Journal of Anesthesia
Year Published: 2017

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.