Two-piece ALIF cage optimizes the bone–implant interface in a 360° setting

Photo from wikipedia

IntroductionClinical research has documented that cage subsidence and the loss of balance correction is a significant complication related to spinal fusion. Subsidence is a multifactorial complication, where implant design is… Click to show full abstract

IntroductionClinical research has documented that cage subsidence and the loss of balance correction is a significant complication related to spinal fusion. Subsidence is a multifactorial complication, where implant design is one important element. The aim of the study is to compare the rigidity and bone–implant relative motion of segments treated with either a conventional one-piece ALIF cage versus a two-piece ALIF cage, which adapts in situ and permits 7°–21° of lordosis.MethodsSeven lumbosacral (L3-S1) human cadaver specimens were tested in a universal spine tester in the intact condition, the specimens instrumented with a two-piece ALIF cage (Statur®-L, FBC Device, Denmark) and a one-piece ALIF cage (Pezo™-A, Ulrich GmbH & Co. KG., Germany), both supplemented with a pedicle screw system using pure moments of ±7.5 Nm in three principal motion directions. For assessment of the bone–implant interface, fluoroscopic videos were captured during motion and 3D motion was measured using an optical motion capturing system.ResultsSignificantly less motion at the implant–endplate interface was found for the two-piece cage (1.0° ± 0.6°) in comparison to the one-piece cage (4.2° ± 1.7°) in flexion/extension. No significant differences in segment rigidity were found between the one-piece and two-piece cages in the 360° setup, while both configurations significantly reduced the range of motion compared to the intact condition (p < 0.05).ConclusionIn comparison to the traditional one-piece ALIF cages, the two-piece cage concept reduced the relative motion at the bone–implant interface without compromising stability.

Keywords: motion; piece; piece alif; two piece; cage; alif cage

Journal Title: European Spine Journal
Year Published: 2017

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.