LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Influence of sharpening filters on the detection of root fractures using low-dose cone-beam computed tomography.

Photo by kimdonkey from unsplash

OBJECTIVES To evaluate the influence of sharpening filters in the detection of root fractures using low-dose cone-beam computed tomography (CBCT). MATERIALS AND METHODS Eighty-four CBCT volumes acquired at three mA… Click to show full abstract

OBJECTIVES To evaluate the influence of sharpening filters in the detection of root fractures using low-dose cone-beam computed tomography (CBCT). MATERIALS AND METHODS Eighty-four CBCT volumes acquired at three mA levels of 28 teeth inserted in the dental socket of dry human skull were selected from a previous study. The teeth were divided into four groups according to the presence and absence of root fracture and endodontic filling. Five radiologists evaluated all CBCT volumes for the presence of root fracture with and without the application of "Sharpen 1x" and "Sharpen 2x" filters in OnDemand3D software. Area under the ROC curve (AUC), sensitivity, specificity, and inter- and intra-observer concordance were calculated and compared (α = 0.05). RESULTS Sharpening filters did not lead to significant differences in AUC, sensitivity, and specificity at the three mA levels tested (p > 0.05), regardless of the presence of endodontic filling (p > 0.05). However, the significant reduction of AUC observed in CBCT volumes at 4 mA without filter (p < 0.05) ceased to exist after the application of filters (p > 0.05). Sensitivity and specificity ranged from low and moderate. CONCLUSIONS The use of sharpening filters can be recommended in CBCT volumes at 4 mA for root fracture detection for leading to the same performance as those at 6.3 and 10 mA. The presence of endodontic filling material did not influence the action of filters in the diagnosis of root fracture. CLINICAL RELEVANCE Sharpening filters seem to contribute to the diagnosis of root fracture in CBCT volumes acquired with reduced radiation dose.

Keywords: sharpening filters; cbct volumes; influence; root fracture; detection; root

Journal Title: Clinical oral investigations
Year Published: 2022

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.