Recently we described mapping of the lingual nerve clinically in patients using electrical nerve stimulation. This paper reports results of a larger study with inter- and intra-observer reliability and comparison… Click to show full abstract
Recently we described mapping of the lingual nerve clinically in patients using electrical nerve stimulation. This paper reports results of a larger study with inter- and intra-observer reliability and comparison with positional measurements from magnetic resonance imaging (MRI). In 50 healthy participants, measurements were taken when subjects felt a tingling sensation in the tongue induced by a stimulation probe over the lingual nerve. Three positions were measured in relation to the third molar. Measurement reliability was tested for both inter-observer and intra-observer agreement and positional data of the lingual nerve measured clinically was also compared with nerve position as measured from MRI scans. Out of 50 participants, 96 nerves (49 = left/47 = right) were included in the study. The lingual nerve was identified in 90% (87) of this sample. The mean of height of the nerve in points A, B and C were 9.64 mm, 10.77 mm and 12.34 respectively. Inter-and intra-observer agreement was considered to be good to excellent (ICC = 0.8–0.96). Agreement between nerve mapping measured values and MRI measured values was good (ICC < 0.6). This technique may prove useful for the clinical determination of lingual nerve position prior to procedures in the third molar region.
               