LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Implantable loop recorders in the real world: a study of two Canadian centers

Photo from wikipedia

PurposeImplantable loop recorders (ILRs) are increasingly being used for ambulatory electrocardiography. We sought to evaluate ILR indications, diagnostic yield, ILR-guided interventions, and complications in two Canadian centers.MethodsThis was a retrospective… Click to show full abstract

PurposeImplantable loop recorders (ILRs) are increasingly being used for ambulatory electrocardiography. We sought to evaluate ILR indications, diagnostic yield, ILR-guided interventions, and complications in two Canadian centers.MethodsThis was a retrospective study using electronic medical records to identify ILR implants at Queen’s University and the University of Manitoba. Information was collected on patient characteristics, medications, indication for implant, results of prior investigations, diagnostic outcome, and subsequent management.ResultsA total of 540 patients were identified; 386 had completed monitoring at time of analysis. Forty patients were lost to follow-up. Indications were unexplained syncope 84.8%, palpitations 12.8%, and suspected atrial fibrillation 11.7%. For syncope, ILRs documented arrhythmia or conduction disorder in 46%. Most common conditions were asystole/sinus pause (22%), complete heart block (10.4%), and atrial fibrillation (AF) (6.9%). After ILR diagnosis, 39.9% of implanted patients received pacemaker/ICD and 2.7% underwent catheter ablation. For palpitations, ILRs documented arrhythmia or conduction disorder in 60.4%. Most common conditions were AVNRT, AF, complete heart block, and ventricular tachycardia. After diagnosis, 25% underwent catheter ablation and 22.9% received pacemaker/ICD. For suspected AF, AF was diagnosed in 40%. Complications were observed in 3.3% of implanted patients: implant site infection 1.5%, non-infectious implant site pain requiring device removal or pocket revision 1.5%, 0.2% hypertrophic scar, and 0.2% device malfunction.ConclusionsAn ILR has excellent diagnostic yield for syncope, palpitations, and suspected AF, and a considerable proportion of patients undergo ILR-directed interventions following monitoring. ILR implantation is a low-risk procedure.

Keywords: implantable loop; loop recorders; study; canadian centers; two canadian

Journal Title: Journal of Interventional Cardiac Electrophysiology
Year Published: 2017

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.