LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Use of a radiofrequency guidewire to simplify workflow for left atrium access: a case series

Photo by jannerboy62 from unsplash

Transseptal puncture (TSP) is widely used in catheter-based cardiac procedures to gain left atrial access, but its workflow has remained largely unchanged in the last 50 years. This study evaluated… Click to show full abstract

Transseptal puncture (TSP) is widely used in catheter-based cardiac procedures to gain left atrial access, but its workflow has remained largely unchanged in the last 50 years. This study evaluated the safety and efficacy of a novel, simplified technique for TSP with a radiofrequency (RF)-powered guidewire that eliminates multiple exchanges required with standard needles. TSP was performed in 84 patients undergoing left-sided procedures (72 atrial fibrillation ablations [32 RF, 40 cryoballoon], 4 atrial tachycardia ablations, 2 ventricular arrhythmia ablations, 6 left atrial appendage closure) utilizing a stiff, exchange length RF guidewire. Under fluoroscopic and echocardiographic guidance, the RF guidewire was used to facilitate septal puncture with RF energy and provide a rail for advancing catheters to the left atrium without exchange. All procedures were performed under general anesthesia or sedation. TSP was achieved in all patients with no complications. The RF guidewire allowed catheters to be tracked back up to the superior vena cava without exchange in cases where another dropdown was desired to locate a preferred puncture site. The stiffness of the wire provided adequate support to advance all sheaths to the left side regardless of outer diameter. TSP was performed safely and successfully for various left heart procedures with a RF guidewire that served as an RF transseptal device and a stiff guidewire. This allowed for a more efficient and potentially safer technique without the need for re-wiring or an over the wire sheath exchange. This provides substantial savings in both time and materials.

Keywords: radiofrequency; left atrium; workflow; access; guidewire; tsp

Journal Title: Journal of Interventional Cardiac Electrophysiology
Year Published: 2019

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.