LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Adsorption and Leachable Contamination of Flucloxacillin, Cyclosporin and Amiodarone Following Delivery Through an Intravenous Administration Set

Photo from wikipedia

PurposeInteractions between a pharmaceutical drug and its delivery device can result in changes in drug concentration and leachable contamination. Flucloxacillin, amiodarone and cyclosporin were investigated for drug concentration changes and… Click to show full abstract

PurposeInteractions between a pharmaceutical drug and its delivery device can result in changes in drug concentration and leachable contamination. Flucloxacillin, amiodarone and cyclosporin were investigated for drug concentration changes and leachable contamination after delivery through an intravenous administration set.MethodsFlucloxacillin, amiodarone and cyclosporin were delivered through an intravenous administration set and the eluate analysed by HPLC-UV and HPLC-MS.ResultsThe average recovery of flucloxacillin was 99.7% and no leachable compounds were identified. The average recovery of cyclosporin was 96.1%, which contrasts previous findings that have reported up to 50% loss of cyclosporin. This is likely due to the use of DEHP-free administration sets in this study, as adsorption of cyclosporin is linearly related to DEHP content. The average recovery of amiodarone was 91.5%. 5-hydroxymethylfurfural was identified in the amiodarone solution following delivery through the administration set as well as the 5% glucose solution used for delivery.ConclusionsDrug/administration set interactions may modify pharmaceuticals during delivery. In this study, only 90% of the amiodarone was delivered through a generic administration set. Given the growing use of generic administration sets in hospital settings, validation of the suitability of their use is required to ensure patient safety and expected levels of efficacy.

Keywords: administration; amiodarone; delivery; leachable contamination; administration set; intravenous administration

Journal Title: Pharmaceutical Research
Year Published: 2018

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.