Evaluation of Maintained Load Test (MLT) and Pile Driving Analyzer (PDA) in Measuring Bearing Capacity of Driven Reinforced Concrete Piles

Photo from wikipedia

Results of several full scale RC (reinforced concrete) pile load tests were studied and analyzed to create a comparison between the MLT (maintained load test) and PDA (pile driving analyzer)… Click to show full abstract

Results of several full scale RC (reinforced concrete) pile load tests were studied and analyzed to create a comparison between the MLT (maintained load test) and PDA (pile driving analyzer) methods. The ultimate pile capacities derived from analysis of PDA were consistently higher than results from the MLT. A coefficient of 0.9 or a 10% reduction is suggested to be applied to values derived from PDA. It is also observed that the longer the time interval, the greater the shaft friction contribution is towards the pile capacity.

Keywords: maintained load; load test; pda; driving analyzer; reinforced concrete; pile driving

Journal Title: Soil Mechanics and Foundation Engineering
Year Published: 2017

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.