LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

An analytical approach for the simulation of realistic low-dose fluoroscopic images

PurposeThe quality of X-ray images plays an important role in computer-assisted interventions. Although learning-based denoising techniques have been shown to be successful in improving the image quality, they often rely… Click to show full abstract

PurposeThe quality of X-ray images plays an important role in computer-assisted interventions. Although learning-based denoising techniques have been shown to be successful in improving the image quality, they often rely on pairs of associated low- and high-dose X-ray images that are usually not possible to acquire at different dose levels in a clinical scenario. Moreover, since data variation is an important requirement for learning-based methods, the use of phantom data alone may not be sufficient. A possibility to address this issue is a realistic simulation of low-dose images from their related high-dose counterparts.MethodWe introduce a novel noise simulation method based on an X-ray image formation model. The method makes use of the system parameters associated with low- and high-dose X-ray image acquisitions, such as system gain and electronic noise, to preserve the image noise characteristics of low-dose images.ResultsWe have compared several corresponding regions of the associated real and simulated low-dose images—obtained from two different imaging systems—visually as well as statistically, using a two-sample Kolmogorov–Smirnov test at 5% significance. In addition to being visually similar, the hypothesis that the corresponding regions—from 80 pairs of real and simulated low-dose regions—belonging to the same distribution has been accepted in 81.43% of the cases.ConclusionThe results suggest that the simulated low-dose images obtained using the proposed method are almost indistinguishable from real low-dose images. Since extensive calibration procedures required in previous methods can be avoided using the proposed approach, it allows an easy adaptation to different X-ray imaging systems. This in turn leads to an increased diversity of the training data for potential learning-based methods.

Keywords: image; low dose; dose images; simulation; dose; ray

Journal Title: International Journal of Computer Assisted Radiology and Surgery
Year Published: 2019

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.