LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

New technology REMS for bone evaluation compared to DXA in adult women for the osteoporosis diagnosis: a real-life experience

Photo from wikipedia

Summary Osteoporosis is a prevalent skeletal disorder in postmenopausal women. REMS represents a potential technology for osteoporosis diagnosis in clinical practice. Objective To assess the accuracy of Radiofrequency Echographic Multi… Click to show full abstract

Summary Osteoporosis is a prevalent skeletal disorder in postmenopausal women. REMS represents a potential technology for osteoporosis diagnosis in clinical practice. Objective To assess the accuracy of Radiofrequency Echographic Multi Spectrometry (REMS) technology in diagnosing osteoporosis in comparison with dual X-ray absorptiometry (DXA) on a population of Brazilian women. Methods A population of women age ranged between 30 and 80 was recruited at DXA Service of São Paulo School-Hospital, Brazil. They underwent REMS and DXA scans at the axial sites. The REMS accuracy for the osteoporosis diagnosis was evaluated in comparison with DXA on both sites. The intra-operator and inter-operator coefficient of variation (CV) was also calculated. Results A total of 343 patients were enrolled in the study. Erroneous scans due to poor quality acquisitions with both methods or to other technical reasons were excluded; 227 lumbar spine exams and 238 hip exams were acceptable for comparison analysis. The comparison between REMS and DXA outcomes showed that the average difference in BMD (expressed as bias±1.96 SD) was −0.026±0.179g/cm 2 for the spine and −0.027±0.156g/cm 2 for the femoral neck. When accepted 0.3 tolerance on T-score, there were no cases diagnosed as osteoporosis by DXA that were defined as normal by REMS. The REMS intra-operator CV was 0.51% for the lumbar spine and 1.08% for the femoral neck. The REMS inter-operator CV was 1.43% for the lumbar spine and 1.93% for the femoral neck. Conclusion The REMS approach had high accuracy for the diagnosis of osteoporosis in comparison with DXA in adult women. According to our results, this new technology has shown to be a promising alternative for populations without access to DXA densitometry.

Keywords: osteoporosis; osteoporosis diagnosis; dxa; technology; comparison

Journal Title: Archives of Osteoporosis
Year Published: 2021

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.