LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Stapler-Less Robotic Partial Gastrectomy: a Safety and Feasibility Experimental Study

Photo from wikipedia

BackgroundNo true preliminary work has been performed and published on the use of the bipolar cautery devices for transection of the stomach when performed as a part of the sleeve… Click to show full abstract

BackgroundNo true preliminary work has been performed and published on the use of the bipolar cautery devices for transection of the stomach when performed as a part of the sleeve gastrectomy or gastric wedge resection. The objective of this study was to investigate the feasibility and safety of substitution of linear surgical stapling devices for use of a bipolar electrosurgical sealing instrument in the performance of a totally robotic partial gastrectomy (TRPG).MethodsTen female pigs were assigned to an intervention or control group. Intervention included TRPG with a robotic bipolar tissue coagulation device. In the control group, TRPG was performed using the staplers. Assessed outcomes included presence of the intraoperative and postoperative bleeding or leak and features of the sections from the stapled line or sutured line.ResultsMean operating time was (130 ± 31 min) and (87 ± 23 min) in the study and control groups (p = 0.03). Intraoperative gastroscopy revealed slow bleeding associated with the staple line in 3/5 control pigs; oozing was not appreciated in any of the study pigs (0/5). No leak was detected during intraoperative gastroscopy. No major complications were suspected postoperatively or identified at postmortem exam in either group. Mean injury width was (1.12 ± 0.93 mm) in the control group with greater mean injury width (7.88 ± 3.73 mm) in the study group (p = 0.001). Mean depth of ulceration was (0.99 ± 0.94 mm) in the control group, with greater mean ulceration depth (2.25 ± 0.84 mm) in the study group (p = 0.002).ConclusionThe study showed the technical feasibility of performing stapler-less gastric wedge resection. The electrocautery alone failed to demonstrate the technical feasibility which was obtained with the concomitant use of a tissue clamp and a suture.

Keywords: robotic partial; control; gastrectomy; group; study; feasibility

Journal Title: Obesity Surgery
Year Published: 2018

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.