Safety and efficacy of the percutaneous thoracic endovascular repair with regional anesthesia

Photo from wikipedia

Thoracic endovascular aortic repair (TEVAR) is typically performed with general anesthesia (GA) and surgical cutdown (G-TEVAR). As the latest generation of TEVAR delivery systems are smaller, we introduced percutaneous TEVAR… Click to show full abstract

Thoracic endovascular aortic repair (TEVAR) is typically performed with general anesthesia (GA) and surgical cutdown (G-TEVAR). As the latest generation of TEVAR delivery systems are smaller, we introduced percutaneous TEVAR with regional anesthesia (RA) (R-TEVAR) and an arteriotomy closure device. In this study, we compare the safety and efficacy of R-TEVAR to that of the G-TEVAR. This single-center observational study included consecutive patients who underwent either G-TEVAR between January 2015 and October 2018 (33 patients) or R-TEVAR (41 patients) between January 2018 and April 2020. RA was achieved using an ultrasound-guided nerve block. The mean outer diameter of the delivery device was significantly smaller in R-TEVAR (18.5 vs. 22.7 Fr; p < 0.01) and the time from arriving into the operating room to beginning of surgery (34.1 vs. 68.5 min; p < 0.01), procedural time (46.4 vs. 103.6 min; p < 0.01), and operating room stay time (108.3 vs. 194.6 min; p < 0.01) were significantly shorter. The mean rate of change in blood pressure was significantly lower in the R-TEVAR group (7.7% vs. 32.2%; p < 0.01). One case of spinal cord ischemia occurred in the G-TEVAR group (0% vs. 3.0%; p = 0.262) and one case of inadequate hemostasis and conversion to surgical cutdown without GA occurred in the R-TEVAR group (2.4% vs. 0%; p = 0.366). The R-TEVAR is safe and minimally invasive. Further, RA may provide additional benefits of mean blood pressure stability and early recognition of neurologic complications.

Keywords: thoracic endovascular; regional anesthesia; safety efficacy; thoracic; tevar; repair

Journal Title: General Thoracic and Cardiovascular Surgery
Year Published: 2020

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.