LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Response to Letter to the Editor: Evaluation of a New Catheter for Simultaneous Intracranial Pressure Monitoring and Cerebral Spinal Fluid Drainage: A Pilot Study

Photo from wikipedia

1. We acknowledge that 34 recordings from six patients is a small sample size of subjects. The study is intended as a pilot study needing validation in larger sample sizes… Click to show full abstract

1. We acknowledge that 34 recordings from six patients is a small sample size of subjects. The study is intended as a pilot study needing validation in larger sample sizes for the reasons provided by Olson et al. However, the study size is deceptive, since there are over 4200 data points, and high-resolution time–frequency data, with waveform analysis applied to the data set. Hence, the relatively short duration and small number of subjects offer high data quality that would likely degrade with longer duration sampling and larger numbers of subjects. There is a trade-off between quality and quantity. 2. We acknowledge that our conclusion ‘there is concordance between ICPf and ICPe’ is only demonstrated when the external ventricular drain is clamped (i.e., cerebral spinal fluid [CSF] drainage is not occurring). Validating ICPf during periods of drainage by direct comparison with another ICP waveform would require placement of an additional ICP monitor into the brain [2–5], which would increase patient risk. While we do not validate ICPf during CSF drainage in this study per se, we think that ICPf when measured during periods of drainage does provide clinically useful data. While there may be a theoretical difference in the function of the sensor during periods of drainage, the CSF flow rate is low and CSF turbulence is unlikely to significantly affect the performance of the sensor. Additionally, the contour of the ICPf waveform does not abruptly change at the onset of drainage suggesting the sensor continues to provide useful information. 3. We agree that the difference between mean ICP from the two sources is not statistically different—in our study a mean difference of − 1.69 mmHg was registered and the measurements from one source crossing the important threshold of 20 mmHg are not necessarily in agreement with measurements from another sources. To be able to accurately pinpoint the source(s) of this differences would be impossible without ensuring measurement from both sources were done after zeroing the sensors properly and according to the same reference point. Therefore, in future studies, a more rigorous control and execution of the ICP sensor zeroing will be needed. 4. We appreciate the good suggestion about re-creating Fig. 3 using the technique used in Fig. 5. We replotted Fig. 3 accordingly, and the data points were divided into three clusters as shown below. Traumatic brain injury patients’ data concentrate around *Correspondence: [email protected] 1 Department of Physiological Nursing, University of California, 2 Koret Way, San Francisco, CA 94143, USA Full list of author information is available at the end of the article

Keywords: cerebral spinal; pilot study; spinal fluid; study; drainage

Journal Title: Neurocritical Care
Year Published: 2019

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.