LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Application of Ultrasonic Assisted-Dispersive Solid Phase Extraction Based on Ion-Imprinted Polymer Nanoparticles for Preconcentration and Trace Determination of Lead Ions in Food and Water Samples

Photo from wikipedia

In this paper, we describe ultrasonic assisted-dispersive solid phase extraction based on ion-imprinted polymer (UA-DSPE-IIP) nanoparticles for the selective extraction of lead ions. Ultrasound is a good and robust method… Click to show full abstract

In this paper, we describe ultrasonic assisted-dispersive solid phase extraction based on ion-imprinted polymer (UA-DSPE-IIP) nanoparticles for the selective extraction of lead ions. Ultrasound is a good and robust method to facilitate the extraction of the target ions in the sorption step and elution of the target ions in the desorption step. The ion-imprinted polymer nanoparticles used in the UA-DSPE-IIP were prepared by precipitation polymerization technique. The ion-imprinted polymer nanoparticles was synthesized using 2-vinylpyridine as a functional monomer, ethylene glycol dimethacrylate as the cross-linker, 2,2′- azobisisobutyronitrile as the initiator, 1,3,4-thiadiazole-2,5-dithiol as the ligand, methanol/dimethyl sulfoxide as the solvent, and lead as the template ion, through precipitation polymerization technique. The IIP nanoparticles were characterized by Fourier transformed infra-red spectroscopy (FTIR), thermogravimetric and differential thermal analysis (TGA/DTA), and scanning electron microscopy (SEM). Box-Behnken design (BBD) was used for optimization of sorption and desorption steps in UA-DSPE-IIP. In the sorption step: pH of solution, IIP amount (mg), sonication time (min) for sorption and in the desorption step: concentration of eluent (mol L−1), volume of eluent (mL), and sonication time (s) for desorption was investigated and optimized by the Box-Behnken design. The optimum conditions for the method were pH of solution: 7.5, sonication time for sorption 7.5 min, IIP amount 24 mg, type and concentration of eluent HCl 1.4 mol L−1, volume of eluent 2.1 mL, and sonication time for desorption 135 s. Under the optimized conditions, the limit of detection and relative standard deviation for the detection of lead ions by UA-DSPE-IIP was found to be 0.7 μg L−1 and <4%, respectively.

Keywords: ion imprinted; extraction; lead ions; imprinted polymer; ion; iip

Journal Title: Food Analytical Methods
Year Published: 2017

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.