A case of rupture of right coronary sinus of Valsalva aneurysm after aortic root replacement due to Stanford type A aortic dissection 15 years ago

Photo by rgaleriacom from unsplash

A 70-year-old Japanese man presented with symptom of a dyspnea and diagnosed as rupture of right coronary of sinus of Valsalva aneurysm. He had a history of ascending aortic replacement… Click to show full abstract

A 70-year-old Japanese man presented with symptom of a dyspnea and diagnosed as rupture of right coronary of sinus of Valsalva aneurysm. He had a history of ascending aortic replacement because of Stanford type A aortic dissection 15 years ago. Cardiovascular examination revealed a grade IV/VI continuous cardiac murmur at the right second intercostal space. Transthoracic echocardiography (TTE) revealed shunt through from right coronary sinus of Valsalva aneurysm to right ventricle detected by color Doppler (Fig. 1a) Twoand three-dimensional transesophageal echocardiography (3DTEE) revealed a ruptured aneurysm of the right coronary sinus of Valsalva causing a large leftto-right shunt through into the right ventricle (Fig. 1b) and defect in right coronary sinus of Valsalva during cardiac cycle (Fig. 1c, d). We decided to perform re-ascending aorta replacement with aortic valve replacement. A ruptured coronary aneurysm was observed in the right sinus of Valsalva. The rupture site was accompanied by the destruction of the wall structure (Fig. 1e). Photomicrograph showing the inner wall of the excised artificial blood vessel. Fibrous capsule appears (black arrow) and fibrin deposition is also observed (white arrow) (hematoxylin and eosin stain, original magnification 3 × 20 × 2) (Fig. 1f). We experienced a case of ruptured sinus of Valsalva aneurysm after ascending aortic replacement for Stanford type A dissection 15 years ago. In this case, gelatin–resorcin–formalin (GRF) glue was used for ascending aortic replacement. The surgical performance of acute aortic dissection had greatly improved by the appearance of GRF glue since 1980. However, stump-plasty using GRF glue has been reported to cause postoperative anastomotic complications in 5–20% [1, 2]. Pathological examination showed fragility of the aorta media and coagulation necrosis due to formalininduced tissue injury [3]. Although GRF glue is rarely used, it had been used in many cases previously. Therefore, it is necessary to observe the occurrence of anatomic complications carefully over the long term.

Keywords: replacement; coronary sinus; right coronary; sinus valsalva; valsalva

Journal Title: Journal of Echocardiography
Year Published: 2021

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.