LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Letter to the Editor Regarding: “Agreement Between Trend-Based and Qualitative Analysis of the Retinal Nerve Fiber Layer Thickness for Glaucoma Progression on Spectral-Domain Optical Coherence Tomography”

Photo from wikipedia

I read with great interest the article by Thompson et al. [1], regarding the detection of glaucoma progression by optical coherence tomography (OCT) retinal nerve fiber layer (RNFL) thickness analysis.… Click to show full abstract

I read with great interest the article by Thompson et al. [1], regarding the detection of glaucoma progression by optical coherence tomography (OCT) retinal nerve fiber layer (RNFL) thickness analysis. The results of this study revealed that the presence of artifacts affected progression detection. As an example, the authors presented a case (Fig. 2) with an epiretinal membrane around the optic nerve head. In the figure legends, the authors commented: ‘‘However, the raw optical coherence tomography B-scans in the upper right panels demonstrate that this change is due to a decrease in traction from the epiretinal membrane, and is thus an example of false progression.’’ I agree that this change is a false progression. I would like to suggest another possible cause of this phenomenon. In the fundus image, a prominent RNFL with thick striae around the optic nerve head is visible, and splitting of the RNFL with the presence of schisis cavities within the RNFL is found on the OCT B-scan images. These findings can be observed in conditions with peripapillary retinoschisis [2]. If the RNFL margins automatically identified by the OCT algorithm include the schisis cavity, it may cause RNFL thickening (Fig. 1) [2]. In the case presented in Fig. 2, RNFL thickening was observed in the first test (schisis cavity between the anterior and posterior RNFL borders), and the inner border of RNFL (red curved line) did not include the schisis cavity for the segmentation of RNFL in the most recent test. This change may be another cause of false RNFL thinning in this case.

Keywords: coherence tomography; rnfl; optical coherence; nerve; progression

Journal Title: Ophthalmology and Therapy
Year Published: 2021

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.