LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Hydrophilic interaction liquid chromatography-mass spectrometry as a new tool for the characterization of intact semi-synthetic glycoproteins.

Photo from wikipedia

Improved methods for detailed characterization of complex glycoproteins are required in the growing sector of biopharmaceuticals. Hydrophilic interaction liquid chromatography (HILIC) coupled to high resolution (HR) time-of-flight mass spectrometric (TOF-MS)… Click to show full abstract

Improved methods for detailed characterization of complex glycoproteins are required in the growing sector of biopharmaceuticals. Hydrophilic interaction liquid chromatography (HILIC) coupled to high resolution (HR) time-of-flight mass spectrometric (TOF-MS) detection was examined for the characterization of intact neo-glycoproteins prepared by chemical conjugation of synthetic saccharides to the lysine residues of selected recombinant proteins. The separation performances of three different amide HILIC columns (TSKgel Amide-80, XBridge BEH and AdvanceBio Glycan Mapping) were tested. Water-acetonitrile gradients and volatile eluent additives have been explored. Addition of 0.05% (v/v) trifluoroacetic acid to the mobile phase appeared to be essential for achieving optimum resolution of intact glycoforms and minimal ion suppression effects. Gradient elution conditions were optimized for each protein on every column. HILIC stationary phases were evaluated for the analysis of highly heterogeneous semi-synthetic derivatives of the same protein (ribonuclease A), and in the enhanced characterization of TB10.4 and Ag85B glycoconjugates, selected antigens from Mycobacterium tuberculosis (MTB). HILIC-MS results indicated that the HILIC selectivity is predominantly governed by size of the conjugated glycans and number of glycans attached, providing efficient glycoform separation. Moreover, HILIC separation prior to HRMS detection allowed assignment of several product impurities. Additional top-down MS/MS experiments confirmed conjugation at the N-terminus of TB10.4 next to its lysine residue. Overall, the obtained results demonstrate that amide-stationary-phase based HILIC coupled to MS is highly useful for the characterization of intact neo-glycoproteins allowing assessment of the number, identity and relative abundance of glycoforms present in the semi-synthetic products.

Keywords: characterization intact; interaction liquid; semi synthetic; hydrophilic interaction; liquid chromatography; characterization

Journal Title: Analytica chimica acta
Year Published: 2017

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.