LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Late Endothelial progenitor cell-capture stents with CD146 antibody and nanostructure reduce in-stent restenosis and thrombosis.

Photo by nci from unsplash

The restoration of damaged endothelium is promising to reduce side effects, including restenosis and thrombosis, in the stent treatment for vascular diseases. Current technologies based on drug delivery for these… Click to show full abstract

The restoration of damaged endothelium is promising to reduce side effects, including restenosis and thrombosis, in the stent treatment for vascular diseases. Current technologies based on drug delivery for these complications still do not satisfy patients due to invariant recurrence rate. Recently, even if one approach was applied to clinical trial to develop the firstly commercialized stent employing circulating endothelial progenitor cells (EPCs) in blood vessels, it resulted in failure in clinical test. Based on instruction of the failed case, we designed an advanced EPC-capture stent covered with anti-CD146 antibody (Ab) immobilized silicone nanofilament (SiNf) for the highly efficient and specific capture of not early but late stage of EPCs. In vitro cell capture test demonstrates enhanced capture efficiency and adhesion morphology of late EPCs on the modified substrate. The modified substrates could capture 8 times more late EPCs and even 3 times more mesenchymal stem cells (MSCs) as compared to unmodified one. A porcine model with high similarity to human reproduced in vivo results ideally translated from in vitro cell capture results. As restenosis indicators, lumen area, neointimal rate and stenosis area on modified stents were reduced at the range of 30-60% as compared to those on bare metal stent (BMS). Fibrin score indicating thrombosis was lowered less than half as compare to that on BMS. These inspiring results are attributed to ∼2-fold increased endothelial coverage, determined by immuno-histological staining. Taken together, the CD146 Ab-armed nanofilamentous stent could show great performance in the reduction of thrombosis and restenosis by re-endothelialization due to specific cell capture.

Keywords: cell capture; restenosis; stent; thrombosis; capture

Journal Title: Acta biomaterialia
Year Published: 2020

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.