LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

A Computational Multilayer Model to Simulate Hollow Needle Insertion into Biological Porcine Liver Tissue.

Photo from wikipedia

BACKGROUND Modelling of needle insertion in soft tissue has developed significant interest in recent years due to its application in robot-assisted minimally invasive surgeries such as biopsies and brachytherapy. However,… Click to show full abstract

BACKGROUND Modelling of needle insertion in soft tissue has developed significant interest in recent years due to its application in robot-assisted minimally invasive surgeries such as biopsies and brachytherapy. However, this type of surgery requires real-time feedback and processing which complex computational models may not be able to provide. METHODS In contrast to the existing mechanics-based kinetic models, a simple multilayer tissue model using a Coupled Eulerian Lagrangian based Finite Element method has been developed using the dynamic principle. The model simulates the needle motion for flexible hollow bevel-angled needle (15° and 30°, 22 G) insertion into porcine liver tissue, which includes material parameters obtained from unconfined compression testing of porcine liver tissue. To validate simulation results, needle insertion force and cutting forces within porcine liver tissue were compared with corresponding experimental results obtained from a custom-built needle insertion system. RESULTS For the 15° and 30° bevel-angle needles, the percentage error for cutting force (mean) of each needle compared to computational model, were 18.7% and 11.9% respectively. Varying the needle bevel angle from 30° to 15° results in an increase of the cutting force, but insertion force does not vary among the tested bevel angles. CONCLUSION The validation of this computationally efficient multilayer Finite Element model can help engineers to better understand the biomechanical behaviour of medical needle inside soft biological tissue. Ultimately, this multilayer approach can help advance state-of-art clinical applications such as robot-assisted surgery that requires real-time feedback and processing. STATEMENT OF SIGNIFICANCE The significance of the work is in confirming the effectiveness of multilayer material based finite element (FE) method to model biopsy needle insertion into soft biological porcine liver tissue. A multilayer Coupled Eulerian Lagrangian (CEL) based FE modelling technique allowed testing of heterogeneous, non-linear viscoelastic porcine liver tissue in a system, so direct comparison of needle tissue interaction forces on the intrinsic material (tissue) behaviour could be made. To the best of the authors' knowledge, the present research investigates for the first time modelling of a three dimensional (3D) hollow needle insertion using a multilayer stiffness model of biological tissue using FE based CEL method and presents a comparison of simulation results with experimental data.

Keywords: liver tissue; insertion; tissue; model; needle insertion; porcine liver

Journal Title: Acta biomaterialia
Year Published: 2021

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.