LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Hyperemic versus non-hyperemic indexes for coronary physiology assessment in patients with severe aortic stenosis.

Photo by aleexcif from unsplash

PURPOSE Recent data suggests that fractional flow reserve (FFR) may underestimate intermediate coronary stenosis in the presence of severe aortic stenosis (AS), whereas instantaneous wave-free ratio (iFR) values may remain… Click to show full abstract

PURPOSE Recent data suggests that fractional flow reserve (FFR) may underestimate intermediate coronary stenosis in the presence of severe aortic stenosis (AS), whereas instantaneous wave-free ratio (iFR) values may remain similar after treatment of AS, yet the evidence still lacks to use iFR as the reference. We aimed to compare FFR/iFR values in the AS setting. MATERIALS AND METHODS The functional significance of 416 coronary lesions in 221 patients with severe AS was investigated with iFR and FFR. RESULTS The diagnostic agreement between iFR and FFR has been tested, using the cut-off value of 0.89 for iFR and 0.80 for FFR. The mean diameter stenosis was 58.6 ​± ​13.4% with FFR of 0.85 ​± ​0.07 and iFR of 0.90 ​± ​0.04. FFR ≤0.80 was identified in 26.0% and iFR≤0.89 in 33.2% of interrogated vessels. Good agreement between iFR and FFR was confirmed (Intraclass Correlation Coefficient 0.83 [95%CI 0.79-0.85]). The overall diagnostic accuracy (AUC in ROC analysis) of FFR in detecting iFR≤0.89 was 0.997 (95%CI 0.986 to 1.000; p<0.001) and of iFR in detecting FFR≤0.80 was 0.995 (95%CI 0.983 to 0.999; p<0.001). The optimal cut-off value for FFR to detect iFR≤0.89 was 0.82 with sensitivity, specificity, and accuracy of 97.1%, 98.9%, and 97.7%, respectively, and for IFR to detect FFR≤0.80 was 0.88 with sensitivity, specificity, and accuracy of 99.1%, 95.8%, and 97.4%, respectively. CONCLUSION In the presence of AS, FFR has good agreement with iFR. However, the optimal FFR/iFR threshold to identify iFR≤0.89/FFR≤0.80 may be different from the standard thresholds of ischemia.

Keywords: severe aortic; physiology; ifr ffr; stenosis; ifr; ffr

Journal Title: Advances in medical sciences
Year Published: 2021

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.