LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Impact of COVID-19 on the pre and post analytical clinical laboratory testing processes- A performance evaluation study using six sigma

Photo from wikipedia

Background The aim of this study was to determine the impact of COVID-19 pandemic on the total testing process using six sigma metrics based on a comparison of pre and… Click to show full abstract

Background The aim of this study was to determine the impact of COVID-19 pandemic on the total testing process using six sigma metrics based on a comparison of pre and during pandemic periods. Material & methods The study duration was over 12 months, 6 months before and 6 months after the COVID-19 onset in Pakistan in March 2020 after the recognition of the first case, using quality indicators (QIs). QIs were chosen from a model of QIs recommended by the CAP. Analysis was performed using Six Sigma calculators and QIs were expressed in percentage (%) and Sigma value were computed. Three levels of performance quality i.e. 25th, 50th, and 75th percentile were derived, being best, common and worst performance respectively. Between-group differences were tested using the Mann-Whitney's U test. Results The median defect percentages of these QIs ranged from 0% to 0.27% for the pre-pandemic period and 0% to 0.13% for the during pandemic period. Meanwhile, sigma values of the majority of the QIs were all above 4.0σ during the pre and the pandemic times. For the pre-analytical phase, sigma scores declined for 1 QI, improved for 3 QIs and remained same for 2. In the post analytical phase, no change in sigma metrics was noted for critical values notification. Considerable increase in defect percentage of inappropriate turnaround times was noted. Conclusion The emergency preparedness proved to be fruitful as depicted by exceptional performance on the sigma metrics for most Qis both prior to and during the pandemic. The pre-analytical and the post analytical phases, being the most error sensitive requires strict vigilance.

Keywords: six sigma; post analytical; using six; pre; sigma; performance

Journal Title: Annals of Medicine and Surgery
Year Published: 2021

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.