LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Measured Resection Techniques Do Not Align to the Cylindrical Axis in Kinematic Total Knee Arthroplasty

Photo by nate_dumlao from unsplash

Background There has been increasing interest with improved functional results in kinematically aligned total knee arthroplasty. Kinematic alignment seeks to replicate the rotational axes of the individual knee. The femoral… Click to show full abstract

Background There has been increasing interest with improved functional results in kinematically aligned total knee arthroplasty. Kinematic alignment seeks to replicate the rotational axes of the individual knee. The femoral component can either be aligned to the estimated prearthritic distal and posterior joint lines via a measured-resection technique or by aligning to the cylindrical axis (CA). The CA is calculated using three-dimensional imaging and defined as a line equidistant from the medial and lateral condylar surfaces from 15° to 115° flexion. This study investigates whether these 2 techniques lead to similar alignment angles in the coronal plane. Materials and Methods One hundred three knees undergoing total knee arthroplasty were assessed using a computed tomography-based protocol. The image-based cylindrical axis coronal angle (CAA) was calculated, and the distal condylar coronal angle (DCA) was calculated to simulate a caliper measured resection technique. A computed tomographic planning software program was used to measure the offset from the distal-most extent of the calculated cylinder to the distal-most aspect of the condyles. Results The DCA measured 3.3° valgus (standard deviation 2.4°) and the CAA 1.8° valgus (standard deviation 2.1°). The mean difference in offset from CAA radius to DCA from the medial condyle and the lateral condyle was 2.85 mm and 1.51 mm, respectively, increasing valgus predilection. Conclusions Caliper measured resection kinematically aligned techniques will position the femoral component in a significantly more valgus position than when aligning to the CA of the knee. This is due to an increased offset of the distal femoral articulation from the most distal aspect of the cylinder on the medial side of the knee.

Keywords: cylindrical axis; measured resection; knee arthroplasty; total knee; knee

Journal Title: Arthroplasty Today
Year Published: 2021

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.