LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

In Vivo Assessment of Ascending and Arch Aortic Compliance.

Photo from wikipedia

BACKGROUND Dynamic compliance (Cd) of the adult thoracic ascending and arch aorta has had limited in vivo evaluation in patients with aortic disease. This study evaluates aortic compliance using intravascular ultrasound… Click to show full abstract

BACKGROUND Dynamic compliance (Cd) of the adult thoracic ascending and arch aorta has had limited in vivo evaluation in patients with aortic disease. This study evaluates aortic compliance using intravascular ultrasound (IVUS) across a range of thoracic aortic diseases. METHODS Seventy-nine patients undergoing thoracic aortic endovascular procedures had Cd measurements of the ascending aorta proximal to the origin of the brachiocephalic trunk and distal to the origin of the left common carotid artery using IVUS before endograft deployment. Cd was calculated for each segment using the following equation, Cd = ΔD/(D • ΔP) where ΔD = change in aortic diameter, D = diameter in diastole, and ΔP = pulse pressure. RESULTS Mean Cd of the ascending aorta in all patients (18.4%/mm Hg) and aortic arch (16.5 %/100 mm Hg) did not differ significantly. Compliance was significantly lower in patients being treated for thoracic aortic aneurysm and penetrating ulcer than in patients with traumatic rupture, acute and chronic dissection (P = 0.009). Compliance was significantly higher in patients with aortic transection compared with thoracic aneurysm or penetrating ulcer (P = 0.001). Compliance decreased with age by 0.44 ± 0.06 (P = 0.001) per year in the ascending aorta and 0.41 ± 0.05 (P = 0.001) per year in the aortic arch. Compliance did not increase with diameter when adjusted for age (P = 0.65). Compliance measured in the ascending aorta in 7 patients after descending thoracic aortic endograft repair decreased to 12.6%/100 mm Hg, although not significant (P = 0.18). CONCLUSIONS Ascending and aortic arch compliance is significantly higher than reported for peripheral vessels. Thoracic aortic compliance decreases with age and is not related to aortic diameter. The results of the present study are important when considering the development of endoprosthesis devices and long-term effects on the thoracic aorta.

Keywords: thoracic aortic; ascending arch; arch; ascending aorta; compliance; aortic compliance

Journal Title: Annals of vascular surgery
Year Published: 2019

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.