LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Elastic and surgeon friendly electrospun tubes delivering PDGF-BB positively impact tendon rupture healing in a rabbit Achilles tendon model.

Photo by kris_ricepees from unsplash

A major problem after tendon laceration is the low mechanical strength of the repaired tissue. One viable strategy for improving the functional and biomechanical properties of ruptured and repaired tendons… Click to show full abstract

A major problem after tendon laceration is the low mechanical strength of the repaired tissue. One viable strategy for improving the functional and biomechanical properties of ruptured and repaired tendons is the delivery of growth factors at the injury site. Here, bioactive and reversibly expandable double-layered emulsion and coaxially electrospun tubes made from biodegradable DegraPol® (DP) (polyester urethane), delivering platelet-derived growth factor BB (PDGF-BB), are explored as implants to improve tendon healing in a rabbit Achilles tendon full laceration model. In vitro studies showed that both emulsion and coaxially electrospun scaffolds allow sustained delivery of bioactive PDGF-BB with similar release kinetics (150-190 pg PDGF-BB/mg of DP scaffold) over a period of 30 days. In vivo assessment after three weeks showed that PDGF-BB delivery through the bioactive DP tubes increased the tensile strength of the treated tendons 2-fold without additional pro-fibrotic effects, i.e., cell hyperproliferation or increase in α-smooth muscle actin expression at the wound site. While no major differences in ECM composition at the wound site were observed for ± PDGF-BB treated samples, collagen I and III were upregulated and fibronectin was downregulated compared to native tendons. In areas away from the wound, increased fibronectin expression was observed qualitatively in regions with lower collagen I and III expression. Both types of bioactive DP tubes provided surgeon-friendly and stable implants to deliver bioactive molecules and positively affected the strength of the repaired tendons after 3 weeks, thus presenting promising bioactive implants for clinical applications in the tendon repair field.

Keywords: healing rabbit; surgeon friendly; achilles tendon; electrospun tubes; rabbit achilles; pdgf

Journal Title: Biomaterials
Year Published: 2019

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.