PURPOSE This study characterizes prostatic urethra cross-section to develop a surrogate urethra for accurate prediction of urethral dose during real-time high-dose-rate prostate brachytherapy. MATERIALS AND METHODS Archived preoperative transrectal ultrasound… Click to show full abstract
PURPOSE This study characterizes prostatic urethra cross-section to develop a surrogate urethra for accurate prediction of urethral dose during real-time high-dose-rate prostate brachytherapy. MATERIALS AND METHODS Archived preoperative transrectal ultrasound images from 100 patients receiving low-dose-rate prostate brachytherapy were used to characterize the prostatic urethra, contoured on ultrasound using aerated gel. Consensus contours, defined using majority vote, described commonalities in cross-sectional shape across patients. Potential simplified surrogates were defined and evaluated against the true urethra. The best performing surrogate, a circle of varying size (CS) was retrospectively contoured on 85 high-dose-rate prostate brachytherapy treatment plans. Dose to this recommended surrogate was compared with urethral doses estimated by the standard 6 mm circle surrogate. RESULTS Clear variation in urethral cross-sectional shape was observed along its length and between patients. The standard circle surrogate had low predictive sensitivity (61.1%) compared with true urethra because of underrepresentation of the verumontanum midgland. The CS best represented the true urethra across all validation metrics (dice: 0.73, precision: 67.0%, sensitivity: 83.2%, conformity: 0.78). Retrospective evaluation of planned doses using the CS surrogate resulted in significant differences in all reported urethral dose parameters compared with the standard circle, with the exception of D100%. The urethral dose limit (115%) was exceeded in 40% of patients for the CS surrogate. CONCLUSIONS The proposed CS surrogate, consisting of circles of varying diameter, is simple yet better represents the true urethra compared with the standard 6 mm circle. Higher urethral doses were predicted using CS, and the improved accuracy of CS may offer increased predictive power for urethral toxicity, a subject of future work.
               
Click one of the above tabs to view related content.