LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Repetition rate priority combination method based on equidistant wavelengths screening with application to NIR analysis of serum albumin

Photo by polarmermaid from unsplash

Abstract For the rapid measurement of an analyte in complex samples using near-infrared (NIR) spectroscopy, appropriate wavelength selection is an important and albeit difficult aspect, which is essential for improving… Click to show full abstract

Abstract For the rapid measurement of an analyte in complex samples using near-infrared (NIR) spectroscopy, appropriate wavelength selection is an important and albeit difficult aspect, which is essential for improving prediction performance. Based on equidistant combination partial least squares (EC-PLS), an equivalence model set was proposed. A wavelength selection method, called repetition rate priority combination PLS (RRPC-PLS), was further proposed and applied for NIR analysis of human serum albumin. The competitive adaptive reweighted sampling combined PLS (CARS-PLS) and EC-PLS, which are well-performed wavelength selection methods, were also conducted for comparison. Based on the various divisions of calibration and prediction sets, the modeling was performed to achieve parameter stability. The posterior sample group excluded in modeling was used to validate and achieve an objective evaluation. Using CARS-PLS, EC-PLS and RRPC-PLS methods, the selected optimal models included 32, 36 and 24 wavelengths, respectively. A simpler and high performance model with 15 wavelengths was also selected with RRPC-PLS method. The root-mean-square errors and correlation coefficients for validation were 0.505 g L −1 and 0.997 for the optimal RRPC-PLS model and 0.530 g L −1 and 0.997 for the RRPC-PLS model ( N =15), respectively. The validation effects were superior to the previous two methods in two aspects of prediction performance and model complexity. The prediction values were close to the measured values with high precision. The results showed that RRPC-PLS is the good improvement on EC-PLS, which can be more effective to enhance the prediction performance and remove the redundant wavelengths.

Keywords: pls; combination; rrpc pls; method; model

Journal Title: Chemometrics and Intelligent Laboratory Systems
Year Published: 2017

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.