LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Evaluation of bioaerosols by flow cytometry and removal performance in a biofilter treating toluene/ethyl acetate vapors.

Photo by usgs from unsplash

The removal efficiency (RE) and bioaerosol emission of a perlite biofilter treating vapors of toluene (T) and/or ethyl acetate (EA) were assessed, under different operating conditions, during 171 days. Under… Click to show full abstract

The removal efficiency (RE) and bioaerosol emission of a perlite biofilter treating vapors of toluene (T) and/or ethyl acetate (EA) were assessed, under different operating conditions, during 171 days. Under the first stages of operation, a mixture of EA and T was treated, with equivalent inlet loads (ILs) of each compound (ranging from 26 to 84 g m-3 h-1), achieving a 100% RE of EA, and a maximum elimination capacity (EC) of T of 58.7 g m-3 h-1. An inhibition of T removal was noted in presence of EA, as T was treated subsequently to EA, along biofilter depth. A 17 days starvation period induced no global deterioration of performance regarding EA removal, but a 50% lower RE of T. Suspension of one contaminant, with interspersed feeding of only one component of the mixture, caused a permanent drop of the RE of EA (to 87.3%), after a T only feeding of 41 days. Flow cytometry (FC) was applied for quantification of bioaerosols, allowing for differentiation between viable, dead and damaged cells. During the overall biofilter operation, bioaerosol emission was not statistically different from bioaerosol retention. However, the biofilter significantly emitted bioaerosols (mostly viable cells) during start-up and IL increase, whereas a global retention of dead cells was observed during the interspersed feeding of one contaminant. Bioaerosols measured by FC (107 Cells m-3) were three orders of magnitude greater than with plate counting dishes, indicating that FC does not underestimate bioaerosols as culture dependent techniques.

Keywords: biofilter; toluene ethyl; flow cytometry; biofilter treating; ethyl acetate

Journal Title: Chemosphere
Year Published: 2020

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.