The degradation of nitrobenzene and its intermediate aniline from wastewater by constructed wetlands coupled with the micro-electric field (CW-MEF) technology was studied. The results showed that the CW-MEF system had… Click to show full abstract
The degradation of nitrobenzene and its intermediate aniline from wastewater by constructed wetlands coupled with the micro-electric field (CW-MEF) technology was studied. The results showed that the CW-MEF system had good degradation. With the increase of influent concentration of nitrobenzene, the removal rate of the anode was excellent which remained above 86%, but the degradation of CW-MEF for COD decreased. In different stages, the power generation capacity was different. In the second stage, the power generation voltage reached 430 V and the average power density was 85.07 MW m-3, while the maximum reached 87.47 MW m-3. Through high-throughput sequencing analysis, the A1 sludge layer contained 36% of thick-walled bacteria and 20% of bacteroides, the A2 contained about 20% of campylobacter green, and the A3 contained 10% of green campylobacter, pachyphyte and bacteroides.
               