The impact of configuration of the Ilizarov fixator on its stiffness and the degree of loading of distraction rods

Photo by charlesdeluvio from unsplash

Background: The mechanical parameters of the Ilizarov fixator are influenced by many factors related to its spatial configuration. The aim of this study was to experimentally evaluate the impact of… Click to show full abstract

Background: The mechanical parameters of the Ilizarov fixator are influenced by many factors related to its spatial configuration. The aim of this study was to experimentally evaluate the impact of the type of implant and the number of distraction rods on the uniformity of loading of distraction rods and stiffness coefficients of the Ilizarov fixator. Methods: The tests were carried out on a physical model. The model was mounted in a universal loading station MTS 858 Mini Bionix. Forces in distraction rods are measured with the use of strain gauge force transducers. Displacements of bone fragments were measured by means of digital image correction. Findings: In the case of a fixator with 3 distraction rods, configuration of implants has no statistically significant effect on the forces occurring in distraction rods. In the case of a fixator with 4 distraction rods, there are statistically significant differences in the forces in distraction rods. The highest transverse stiffness coefficients occurs in the system with 4 distraction rods and the configuration of 1K1S implants, while the smallest transverse stiffness coefficients occurs in the fixator with 4 distraction rods and the configuration of 0K1S implants. Interpretation: Based on the results of experiments on the physical model, we observed an asymmetry in the distribution of forces transmitted through distraction rods. The configuration with 3 distraction rods provides more uniform distribution of forces in distraction rods and reduces the impact of the implant configuration on transverse stiffness coefficients. The use of a configurations with 4 rods may be advantageous when we want to obtain greater transverse stiffness coefficients of a system consisting of the fixator and fragments of the lengthened bone. HIGHLIGHTSWe observed an asymmetry in the distribution of forces transmitted through distraction rods.The configuration with three distraction rods provides more uniform distribution of forces in distraction rods.The most uniform distribution of forces transmitted through distraction rods is ensured by the 1K1S configurations.The use of a configurations with 4 rods may be advantageous when we want to obtain greater transverse stiffness coefficients.

Keywords: configuration; distraction rods; stiffness coefficients; fixator; distraction

Journal Title: Clinical Biomechanics
Year Published: 2019

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.