Comparison of four clinically validated testosterone LC-MS/MS assays: Harmonization is an attainable goal.

Photo from wikipedia

Introduction Immunoassays and liquid chromatography-tandem mass spectrometry assays are commonly employed in clinical laboratories for measurement of total testosterone in serum. Results obtained from either of these methodologies compare poorly… Click to show full abstract

Introduction Immunoassays and liquid chromatography-tandem mass spectrometry assays are commonly employed in clinical laboratories for measurement of total testosterone in serum. Results obtained from either of these methodologies compare poorly due to differences in calibration and/or inadvertent detection of interfering substances by the immunoassays. Standardization efforts are underway, but recent studies indicate that accuracy remains an issue. Methods This study compares the results from four independently developed and validated LC-MS/MS assays for total testosterone. The calibration for each assay was verified using National Institute of Standards and Technology Standard Reference Material 971. Results Initially, one of the four assays had a mean percent difference of +11.44%, compared to the All Method Mean, but following re-verification of all five non-zero calibrator concentrations with the NIST SRM 971, the mean percent difference decreased to -4.88%. Subsequently, the agreement between all four assays showed a mean bias of <5% across the range of all testosterone concentrations (0.13-38.10 nmol/L; 3.7-1098 ng/dL), including at low concentrations of <1 nmol/L (<29 ng/dL). Conclusions Excellent agreement between four independently developed LC-MS/MS assays demonstrates that harmonization using standard reference material is attainable. However, as we found in this study, to ensure accurate calibration it is critical to validate the concentrations of new lots of calibrators.

Keywords: comparison four; clinically validated; four clinically; validated testosterone; harmonization; testosterone

Journal Title: Clinical mass spectrometry
Year Published: 2019

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.