LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Differentiation malignant from benign pericardial effusion with diffusion-weighted MRI.

Photo from wikipedia

AIM To differentiate malignant from benign pericardial effusion with diffusion-weighted magnetic resonance imaging (MRI). MATERIAL AND METHODS Retrospective analysis of diffusion-weighted MRI of 41 patients (29 men and 12 women;… Click to show full abstract

AIM To differentiate malignant from benign pericardial effusion with diffusion-weighted magnetic resonance imaging (MRI). MATERIAL AND METHODS Retrospective analysis of diffusion-weighted MRI of 41 patients (29 men and 12 women; mean 39 years) with pericardial effusion. Apparent diffusion coefficient (ADC) of pericardial fluid, and associated pericardial mass or pleural effusion was calculated. ADC of pericardial fluid was calculated by two observers and correlated with cytological analysis. Receiver operating characteristic curves and Bland-Altman plots were used. RESULTS There was significant differences in the ADCs between benign and malignant pericardial effusions (p=0.001) by both observers. Mean ADC of malignant pericardial effusions was (2.92±0.29 and 2.86±0.33×10-3 mm2/s) and of benign effusions was (3.36±0.31 and 3.28±0.28×10-3 mm2/s) for both observers, respectively. The cut-off values of the ADC used for differentiating malignant from benign pericardial effusion were 3.25 and 3.05×10-3 mm2/s with areas under curve of 0.839 and 0.791, sensitivities of 88.2% and 70.6%, specificities of 69.6% and 73.9%, and accuracies of 78% and 72.5% for both observers, respectively. The overall interobserver agreement of the ADC value of pericardial effusion by both observers was significant (r=0.808, p=0.001). The interobserver agreement of malignant effusion (r=0.861, p=0.001) and benign effusion was significant (r=0.659, p=0.001). The ADC of pleural effusion is well correlated with ADC of pericardial effusion (r=0.088, p=0.001). CONCLUSION The ADC value is a non-invasive imaging parameter that can be used for differentiation of malignant from benign pericardial fluid.

Keywords: benign pericardial; diffusion weighted; malignant benign; pericardial effusion; effusion

Journal Title: Clinical radiology
Year Published: 2019

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.