LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

The monitoring of wall moisture in a property retrofitted with Internal Wall Insulation

Photo from wikipedia

Abstract The purpose of this study was to measure the long-term moisture build-up in the walls of a house which had been retrofitted with Internal Wall Insulation. This was done… Click to show full abstract

Abstract The purpose of this study was to measure the long-term moisture build-up in the walls of a house which had been retrofitted with Internal Wall Insulation. This was done by embedding moisture sensors in the walls and then monitoring values over an eight-year period. The results showed that the wall moisture of embedded wood piece sensors had increased to a value of 18–20 % over 8 years. In a comparable wall, which had been treated with water repellent brick cream, the build-up of moisture was significantly reduced to 9–10 % over the same period. This wall was examined after the 8-year period and no visible mould was evident.

Keywords: moisture; wall insulation; wall moisture; wall; retrofitted internal; internal wall