32. Linac based VMAT radiosurgery for multiple brain lesions: comparison between a conventional multi-isocenter approach and a new dedicated mono-isocenter 4π technique (HyperArc™)

Photo by nci from unsplash

Purpose Linac based VMAT radiosurgery (SRS) of multiple brain lesions (MBL) is typically performed by a multiple-isocenter approach, i.e.one isocenter per lesion.Here we present the worldwide first experience with a… Click to show full abstract

Purpose Linac based VMAT radiosurgery (SRS) of multiple brain lesions (MBL) is typically performed by a multiple-isocenter approach, i.e.one isocenter per lesion.Here we present the worldwide first experience with a new mono-isocenter technique with multiple non-coplanar arcs (HyperArc, Varian Inc.)in terms of a plan comparison with a multiple-isocenter approach. Methods From August to October 2017, 20 patients with MBL (mean 5, range 2–10) have been treated by HyperArc: prescribed doses ( D p ) were 18–25 Gy in single-fraction, and 21–27 Gy in three-fractions.Total PTV, defined by a 2 mm isotropic margin from each lesion, had mean size of 9.6 cm3 (range 0.5–27.9 cm3).HyperArc VMAT plans (HA), with 5 non-coplanar 180°-arcs (couch at 0°, ±45°, ±90°), and multiple-isocenter VMAT plans (RA), with 2 coplanar 360°-arcs per isocenter, were generated.100% D p at 98%PTV was prescribed, and D 2 % (PTV) D p was accepted.Constraints for 1(3) -fraction to the brainstem, D 0.5cc D 0.5cc V 12 and mean dose to the brain-minus-PTV, MU and overall treatment time (OTT) per fraction.OTT was measured for HA treatments, whereas estimated (3 min.for patient setup plus 5 min.for each CBCT per isocenter) for RA plans. Results As detailed in Table 1 , HA plans resulted in significantly improved CI ( p V 12 to the brain-minus-PTV (p = .023), MU (p D p isodose shells around the targets for the HA plans is depicted for an example patient.By contrast, no significant difference in terms of mean doses to the brain-minus-PTV resulted (p = .31). Conclusions For linac based VMAT-SRS of MBL, HyperArc plans assured a higher CI and a lower GI, a lower  V 12 to the brain-minus-PTV, and a lower OTT than standard multiple-isocenter VMAT plans. Finally, all HyperArc treatments were completed within a typical 20 min. time slot.

Keywords: based vmat; hyperarc; linac based; isocenter approach; isocenter; brain

Journal Title: Physica Medica
Year Published: 2018

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.