LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

[P061] Calculation of beam quality parameters for X-ray mammography spectra: A monte carlo simulation study

Photo from wikipedia

Purpose Breast cancer is known to be the most malignant type of cancer among women in the world. By X-ray mammographic imaging, the disease can be detected and then an… Click to show full abstract

Purpose Breast cancer is known to be the most malignant type of cancer among women in the world. By X-ray mammographic imaging, the disease can be detected and then an early stage treatment can be started following this. For a reliable imaging, beam quality parameters should be precisely determined. However, measurement of X-ray beam quality parameters necessitates using specific equipment. An efficient way for determining these parameters is to utilize scientifically proven and verified Monte Carlo simulation codes. Methods Monte Carlo simulations are widely used in digital mammography imaging research. In this work, MCNP5 was used for simulating generation of X-ray spectrum including both bremsstrahlung and characteristic X-rays. Electron beam and target (anode) were modelled as specified in the Report of AAPM Task Group 195: Monte Carlo Reference Data Sets for Imaging Research. Results X-ray quality parameters such as Aluminum (Al) equivalent half-value layer (HVL), Al equivalent effective energy, average energy, and air kerma of the simulated polyenergetic X-ray beams were calculated and tabulated for a wide range of commercially available mammographic X-ray tube voltage (kVp) and target/filter material and thickness combinations (molybdenum/molybdenum, molybdenum/rhodium, rhodium/rhodium, tungsten/rhodium, tungsten/silver, and tungsten/aluminum). All calculated parameters were then fitted to second-degree polynomial surface equations as a function of kVp and filter thickness for each target/filter combination. Conclusions This work is essential and flexible in the sense that it provides a reliable and quick look-up database for those performing mammographic patient dose and image quality calculations. In addition, it could be taken as a starting point for generation of quality data for entire diagnostic X-ray energy range, e.g. 20–140 kVp, for any combination of target/filter. On the other hand, with this study, it can be deduced that important mammographic parameters can be precisely calculated with Monte Carlo methods, which would otherwise need for expensive and complicated experimental equipment and much more time.

Keywords: quality; monte carlo; quality parameters; ray; beam

Journal Title: Physica Medica
Year Published: 2018

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.