LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Single source split filter dual energy: Image quality and liver lesion detection in abdominal CT.

Photo from wikipedia

PURPOSE Aim of this study was to evaluate image quality of single source dual energy CT (SSDE-CT) using split filter technique in oncologic abdominal CT. METHOD 51 consecutive patients with… Click to show full abstract

PURPOSE Aim of this study was to evaluate image quality of single source dual energy CT (SSDE-CT) using split filter technique in oncologic abdominal CT. METHOD 51 consecutive patients with newly diagnosed breast carcinoma were prospectively enrolled in this study and underwent a staging examination of the abdomen using SSDE-CT (120 kV, split filter technique, 400 ref. mAs). Inline default images (DI) and post-processed virtual monoenergetic images at 40 keV, 50 keV, 60 keV, 70 keV and 80 keV were reconstructed. Objective image quality was evaluated as contrast to noise ratio (CNR) for liver parenchyma, portal vein, spleen, pancreas, aorta and hypoattenuating liver lesions. Subjective image quality was rated on a 5-point scale. Image quality at different keV settings was analyzed in paired t-tests. RESULTS CNR was highest at 40 keV for vessels (portal vein: 9.0, aorta: 8.8, all p < 0.001) and for upper abdominal organs (spleen: 4.8, all p < 0.001; pancreas: 2.7, all p < 0.01 except p = 0.93 for 50 keV; liver parenchyma: 3.4, all p < 0.01). Highest CNR values for hypoattenuating liver lesions were found at 40 keV (7.7, all p < 0.001). Overall subjective image quality was highest with 80 keV and DI (both 4.8, all p < 0.001). Artifacts were most pronounced at 40 keV. CONCLUSIONS High image quality can be obtained with SSDE-CT of the abdomen. Lowest monoenergetic reconstructions provide the highest image contrast and should be used for vessel evaluation. The best trade-off between artifacts and parenchymal contrast can be obtained with 80 keV images.

Keywords: kev; image; image quality; single source; split filter

Journal Title: European journal of radiology
Year Published: 2020

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.