LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

GFR Estimation After Cystatin C Reference Material Change

Photo from wikipedia

Introduction Glomerular filtration rate (GFR) is routinely estimated with cystatin C. In June 2010, the International Federation of Clinical Chemistry (IFCC) released a certified cystatin C reference material (ERM-DA471/IFCC), and… Click to show full abstract

Introduction Glomerular filtration rate (GFR) is routinely estimated with cystatin C. In June 2010, the International Federation of Clinical Chemistry (IFCC) released a certified cystatin C reference material (ERM-DA471/IFCC), and new cystatin C glomerular filtration rate estimation (eGFR) equations were developed with the IFCC standard. Early in 2018, Siemens discontinued their nonstandardized cystatin C reagent kits and replaced them with IFCC-calibrated kits in the US market. The aim of the current study was to assess the effect of IFCC calibration on cystatin C values and corresponding GFR estimations. Methods Cystatin C concentration was measured in 81 pediatric patients using a plasma sample from their nuclear GFR measurement with 99mTc-diethylenetriaminepentaaccetic acid. Calibration curves were generated using Siemens nonstandardized and IFCC-standardized kits to measure paired cystatin C concentrations in each sample. GFR-estimating equations using pre-IFCC and IFCC cystatin C values were compared using Bland-Altman analyses. Results The IFCC-standardized assay resulted in a mean increase in the measured cystatin C value of 24%. Estimating equations consistently overestimated GFR prior to IFCC standardization. Following incorporation of the IFCC standard, the Full Age Spectrum equation demonstrated the best overall performance, whereas the Chronic Kidney Disease in Children (CKiD) equation was more accurate in children with decreased GFR. Conclusion Incorporation of the IFCC standard significantly increased cystatin C values and affected the performance of GFR estimating equations. Clinical laboratories and providers may need to update the equation used for cystatin C–based estimation of GFR following adoption of the IFCC reference standard.

Keywords: reference material; estimation; gfr; cystatin; cystatin reference

Journal Title: Kidney International Reports
Year Published: 2021

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.