LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

A simple, supersensitive and highly selective electrochemical aptasensor for Microcystin-LR based on synergistic signal amplification strategy with graphene, DNase I enzyme and Au nanoparticles

Photo by introspectivedsgn from unsplash

Abstract As cyanobacteria with high potential hepatotoxicity, Microcystin-LR (MC-LR) in water sample is highly concerned, but is very hard to directly detect by convenient electrochemistry technique due to its lack… Click to show full abstract

Abstract As cyanobacteria with high potential hepatotoxicity, Microcystin-LR (MC-LR) in water sample is highly concerned, but is very hard to directly detect by convenient electrochemistry technique due to its lack of electrochemical activity. In this work, an effective signal-on electrochemical aptasensing platform towards MC-LR has been proposed by designing a synergistic signal amplification system subtly and simply controlled by graphene bi-functional assembly. MC-LR binding aptamers were combined onto graphene surface, obtaining aptamer-graphene complex, and used as recognition element. Au nanoparticles (NPs) were modified onto Au electrode (Au NPs/Au) to act as the probe substrate. When it was functionalized by alkylate thiol, the electron transfer (eT) on Au NPs/Au could be greatly blocked, which could only be recovered by free graphene, while not by aptamer-graphene complex. According to this property, graphene was herein used bi-functionally, serving as not only the binder to recognition element, aptamer, by π-π stacking, but also the eT tunnel regulator to give a concentration-dependent response “turn-on” signal to MC-LR. DNase I enzyme, which can selective cleavage the aptamers bound with MC-LR, was simultaneously added to the system to release MC-LR and to give additional target recycling signal amplification. At the optimized condition, the dose-response curve of MC-LR and the current signal was established with a wide linear range of 1.0–100 pM, and a low detection limit of 0.8 pM, better than many reported literature. Moreover, this aptasensor system shows good selectivity towards MC-LR in the presence of 100-fold other contaminants. The potential sensing principle and recognition mechanism were discussed. A promising and convenient monitoring platform for MC-LR and other organic pollutants has thus been provided.

Keywords: signal amplification; graphene; microcystin; amplification; dnase enzyme; synergistic signal

Journal Title: Electrochimica Acta
Year Published: 2019

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.