LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Dynamic indoor comfort temperature settings based on the variation in clothing insulation and its energy-saving potential for an air-conditioning system

Photo by kingswapy from unsplash

Abstract Saving energy consumption of air-conditioning is essential to building energy conservation while satisfying the thermal comfort requirements of indoor environment. On the basis of human clothing adjustment behavior, a… Click to show full abstract

Abstract Saving energy consumption of air-conditioning is essential to building energy conservation while satisfying the thermal comfort requirements of indoor environment. On the basis of human clothing adjustment behavior, a dynamic setting temperature (DST) that adapts to climate change was proposed in this paper, i.e. indoor air-conditioning setting temperature changes dynamically with outdoor air temperature; furthermore. A method was established to obtain the DST. The daily mean clothing insulation was predicted according to the historical temperature at first, then indoor thermal comfort temperature was calculated based on the variable clothing insulation, and finally the DST was determined. According to the value or range of predicted mean vote (0, -0.5~0.5, -1~+1) corresponding to the thermal comfort, three levels of DST were defined. The corresponding thermal acceptability rates were 95%, 90% and 73%, respectively. A simulation of DST was conducted in a public building in Changsha, China based on meteorological data of 2017. Three levels of DST ranges were obtained, varied from 20.1 to 27.8 °C in level I, 17.8 to 28.7 °C in level II and 15.4 to 29.7 °C in level III, respectively. The simulation results of operational air-conditioning energy consumption shows that the application of DST could save up to 65.5% of energy consumption compared with the traditional fixed setting temperature (FST), and the operational energy consumption decreased by 59.1% due to the application of level-III DST compared with level-I DST. Therefore, the DST proposed in this paper has significant energy saving potential while meeting the thermal comfort requirements.

Keywords: temperature; energy; clothing insulation; comfort; air conditioning

Journal Title: Energy and Buildings
Year Published: 2020

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.