LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

In-plane shear cyclic behavior of windowed masonry walls reinforced with textile reinforced mortars

Photo from wikipedia

Abstract The current experimental study is focused on the mechanical performance of masonry walls under in-plane cyclic shear forces. All specimens were fabricated with a central window, in which the… Click to show full abstract

Abstract The current experimental study is focused on the mechanical performance of masonry walls under in-plane cyclic shear forces. All specimens were fabricated with a central window, in which the geometry considered the recommendations of the Spanish structural seismic design code. Windows represent a weak area in the masonry structure, in which there are stress concentrations responsible for crack initiation. In order to improve the mechanical strength and ductility, a reinforcement with a Textile Reinforced Mortar (TRM) was used on both sides of the wall. The performance of the unreinforced and reinforced masonry has been discussed in terms of strength and ductility gain, stiffness degradation and energy dissipation capacity. The experimental tests comprised an initial vertical preload, and shear cycles with increasing amplitude. All tests were monitored by means of traditional displacement transducers, and digital image correlation. The analysis of the images showed the time evolution of the overall crack distribution. The TRM effect could be observed as an increase of the mechanical strength (maximum shear from 120 kN to more than 300 kN), higher displacements (drift from 9 to 35 mm), and more energy dissipation (the cumulative energy loss from 2.7 to 12.7 kN·m). In addition, the TRM reinforcements were capable of controlling the crack initiation and growth. The widespread crack along mortar joints observed in the unreinforced masonry became localized cracks (from the window’s corners mainly), in which crack growth direction was not determined by masonry joints.

Keywords: plane shear; textile reinforced; crack; masonry; masonry walls

Journal Title: Engineering Structures
Year Published: 2021

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.