LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Permeability of the porcine iris stroma

Photo by harpreetkaka from unsplash

ABSTRACT Current literature has not considered or provided any data on the permeability of the iris stroma. In this study, we aimed to determine the hydraulic permeability of porcine irides… Click to show full abstract

ABSTRACT Current literature has not considered or provided any data on the permeability of the iris stroma. In this study, we aimed to determine the hydraulic permeability of porcine irides from the isolated stroma. Fifteen enucleated porcine eyes were acquired from the local abattoir. The iris pigment epithelium was scraped off using a pair of forceps and the dilator muscles were pinched off using a pair of colibri toothed forceps. We designed an experimental setup, based on Darcy's law, and consisting of a custom 3D‐printed pressure column using acrylonitrile butadiene styrene (ABS) plastic. PBS solution was passed through the iris stroma in a 180° arc shape, with a column height of approximately 204mm (2000Pa). Measurements of iris stromal thickness were conducted using optical coherence tomography (OCT). To measure flow rate, we measured the mass (volume) of PBS solution using a mass balance in approximately 1min. Histology was performed using hematoxylin and eosin (H&E) and anti‐smooth muscle antibody (anti‐&agr;‐SMA) for validation. The permeability experiments demonstrated that the iris stroma is a biphasic tissue that allows fluid flow. Our image processing results determined the area of flow to be 7.55mm2 and the tissue thickness to be between 180 and 430&mgr;m. The hydraulic permeability of the porcine stroma, calculated using Darcy's law, was 5.13±2.39×10−5mm2/Pa•s. Histological and immunochemical studies confirmed that the tissues used for this permeability study were solely iris stroma. Additionally, anti‐&agr;‐SMA staining revealed staining specific for stromal blood vessels, with the notable absence of dilator and sphincter muscle staining. Our study combined experimental microscopic data with the theory of biphasic materials to investigate the hydraulic permeability of the iris stroma. This work will serve as a basis on which to validate future biomechanical studies of human irides with which may ultimately aid disease diagnosis and inform the design of novel treatments. HIGHLIGHTSWe were able to isolate the porcine iris stroma to determine the permeability of the biphasic tissue.A highly permeable iris stroma allows for effective ocular physiology.Permeability of the iris stroma could be directly related to pathologies such as angle closure glaucoma.More accurate finite element (FE) models can be utilized by incorporating the poroelasticity of the iris stroma.

Keywords: stroma; porcine iris; permeability porcine; iris stroma

Journal Title: Experimental Eye Research
Year Published: 2019

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.