A procedure using ICP OES for sample preparation for the determination of copper, iron and manganese in cashew nuts was developed. Constrained simplex-centroid design was applied in the optimization of… Click to show full abstract
A procedure using ICP OES for sample preparation for the determination of copper, iron and manganese in cashew nuts was developed. Constrained simplex-centroid design was applied in the optimization of the digestion in microwave oven procedure, and the results evaluated from topological maps of the Kohonen network. The best proportion evaluated for the digestion of the sample with HNO3, H2O2 and H2O was 10:45:45 (%). With optimized conditions, the detection limits were 0.63, 4.3 and 0.37 mg kg-1, and quantification 2.1, 14 and 1.2 mg kg-1 for Cu, Fe and Mg, respectively. The precision (% RSD) was 1.84, 2.31 and 2.73, for Cu, Fe and Mg, respectively. The procedure proposed had the accuracy confirmed using NIST 1568b (at 95% reliability) and was applied in the samples obtaining concentrations in the range of 10.7-19.4, 44.3-67.2 and 11.0-21.4 mg kg-1 for Cu, Fe and Mg, respectively.
               