LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Reliability in ultrasound measurements of plantar aponeurosis thickness.

Photo from wikipedia

PURPOSE Given the increasing research interest in ultrasound plantar aponeurosis (PA) thickness measurements, this study aimed to analyze the inter and intra-rater reliability of independent sonograms and to identify the… Click to show full abstract

PURPOSE Given the increasing research interest in ultrasound plantar aponeurosis (PA) thickness measurements, this study aimed to analyze the inter and intra-rater reliability of independent sonograms and to identify the error related to the image analysis procedure. METHODS Twenty-one healthy men participated in this study. Imaging of PA consisted of two independent sonograms per subject. Two raters (R1 and R2) evaluated each sonogram twice using standardized steps. Precision of the image analysis procedure was analyzed using the Bland and Altman plot and Intraclass Correlation Coefficient (ICC). Agreement estimates and ICC were used to assess absolute and relative inter and intra-rater reliability. RESULTS Reliability of PA thickness was found to depend strongly on the number of images acquired per subject. Intra-rater agreement for single measurements were 0.696 (R1) and 0.495 (R2), whereas average measurements yielded values of 0.821 (R1) and 0.662 (R2), respectively. Precision within a sonogram varied from ICC values of 0.873 to 0.960 (intra-rater) and 0.670 to 0.822 (inter-rater). CONCLUSION Most part of the error in PA thickness measurements seems to be related to the sonogram acquisition process and not to the visual inspection of the image. To minimize error, average values of a minimum of two images per subject should be used. The moderate agreement between raters found in this study ratifies the need of all measurements being made by the same rater or group of raters. If a single rater evaluates all subjects, performing multiple measurements over one image does not seem to affect ICC as much as acquiring multiple images.

Keywords: plantar aponeurosis; aponeurosis thickness; intra rater; reliability; rater; thickness

Journal Title: Foot
Year Published: 2020

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.