Purpose The aim of this study was to assess the image quality and diagnostic performance of reconstructed arterial (A) and portal venous (PV) phases in computed tomography perfusion (CTP) scans… Click to show full abstract
Purpose The aim of this study was to assess the image quality and diagnostic performance of reconstructed arterial (A) and portal venous (PV) phases in computed tomography perfusion (CTP) scans compared to the corresponding phases in standard 4-phase CT and to assess the utility for LI-RADS classification using CTP and 4-phase 4CT. Methods A total of 26 scans with each method (CTP and 4-phase CT) from 19 hepatocellular carcinoma patients were analyzed and compared. Arterial and PV phases reconstructed by advanced modeled iterative reconstruction at strength 4 (ADMIRE 4) from raw CTP data were compared with image sets from arterial and PV phases of 4-phase CT (ADMIRE 3) in the same patient with respect to image quality. Results Quantitative image analysis showed that reconstructed CTP datasets were equivalent to 4-phase CT image sets. Qualitative image analysis revealed similar lesion detection rates with the 2 methods for patients with an abdominal diameter ≤36 cm and body weight <90 kg, but lower detection rates with CTP for patients with an abdominal diameter >37 cm. There was no difference in Liver Imaging Reporting and Data System (LI-RADS) classifications between the 2 methods. Conclusion Reconstructed CTP images can potentially replace 4-phase CT images in patients weighing <90 kg and with a body diameter <37 cm, as the 2 methods are comparable in terms of quantitative image quality and ability to detect and classify lesions based on LI-RADS criteria.
               