LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Comparison of longevity and clinical outcomes of implantable cardioverter-defibrillator leads among manufacturers.

Photo by goian from unsplash

BACKGROUND An early failure of the Biotronik Linox S/SD implantable cardioverter-defibrillator (ICD) lead has been reported. We have also experienced several cases with early failure of Linox leads. OBJECTIVE Our… Click to show full abstract

BACKGROUND An early failure of the Biotronik Linox S/SD implantable cardioverter-defibrillator (ICD) lead has been reported. We have also experienced several cases with early failure of Linox leads. OBJECTIVE Our aim was to assess the longevity of Linox S/SD (Biotronik, Berlin, Germany) compared with Sprint Fidelis (Medtronic, Minneapolis, MN), Sprint Quattro (Medtronic), and Endotak Reliance (Boston Scientific, Natick, Massachusetts) leads. METHODS We retrospectively reviewed patients who had undergone implantation of Linox S/SD (n = 90), Sprint Fidelis (n = 37), Sprint Quattro (n = 27), or Endotak Reliance (n = 50) leads between June 2000 and December 2013 at our hospital. Variables associated with lead failure were assessed by the Kaplan-Meier method and Cox survival modeling. RESULTS Failure rates of Linox, Sprint Fidelis, and Endotak leads were 3.2%/year (7-year survival rate, 81.0%), 3.4%/year (7-year survival rate, 77.2%), and 0.61%/year (7-year survival rate, 95.8%), respectively. No lead failure was found with Sprint Quattro leads. The survival probability of Linox leads was significantly lower than that of Endotak leads (P = .049) and comparable to that of Sprint Fidelis leads (P = .69). In univariate analysis, age was the only predictor of Linox lead failure. Patients <58 years old were at significantly increased risk of lead failure compared with patients ≥58 years old (hazard ratio, 9.0; 95% confidence interval, 1.13-71.3; P = .037). CONCLUSION In our single-center experience, the survival rate of Linox leads was unacceptably low. The only predictor of Linox lead failure was age at implantation. This is the first description of a lower survival rate for Linox leads in an Asian population.

Keywords: sprint; survival rate; year; lead failure; failure

Journal Title: Heart rhythm
Year Published: 2017

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.