LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Is Transesophageal Echocardiography alone sufficient for detecting prosthetic mitral valve vegetation?

Photo from wikipedia

Infective endocarditis (IE) is a lethal diseasewith highmortality and morbidity. Therefore early diagnosis and treatment is highly recommended, and echocardiography has the main role in diagnosis of IE, Prosthetic valve… Click to show full abstract

Infective endocarditis (IE) is a lethal diseasewith highmortality and morbidity. Therefore early diagnosis and treatment is highly recommended, and echocardiography has the main role in diagnosis of IE, Prosthetic valve endocarditis is more aggressive form and affect the patient survival significantly. It is seen in 1–6% of patients with prosthetic valve, and includes 10–30% of all IE cases. Both transthoracic (TTE) and transesophageal echocardiography (TEE) are imaging modalities of choice for diagnosis, management and follow up of IE. TTE should be performed as soon as possible in all patients with clinical evidence of IE, and TEE should also done for better and precise diagnosis in concomitant with evaluation of complications; really TEE is recommended when the TTE is suspicious of IE or for further evaluation of high risk conditions such as the presence of prosthetic valves, native valves’ regurgitant or stenotic lesions and in the presence of other intracardiac devices. Repeating TTE and or TEE examination within 5–7days in case of initially negative echo exam in the presence of high clinical suspicion is recommended. Vegetation, abscess or pseudoaneurysm and a new dehiscence of prosthetic valve are findings in echocardiography which are major criteria for IE. Overall, TTE has lower sensitivity for detection of vegetation in compared with TEE (40–60% vs. 94–100%). False negative results are usually due to small or non-oscillating vegetations, vegetations in atypical position, vegetations which have embolized and also cause of acoustic shadowing of the prosthetic valve . In some circumstances TEE is initially suggested and performed such as in the presence of prosthetic valve, Poor TTE image quality, calcified aortic valve and myxomatous mitral valve due to added value of TEE in compared with TTE; for example Biswas A, et al., studied 27 high risk patients for IE that underwent TTE and TEE examinations and only 29.6% of patients was found to have vegetation on TTE; This study recommend TEE as the initial diagnostic tool for high risk patients without need for TTE They saw risk benefit ratio was in favor of doing TEE without preceding TTE in high risk individuals; however, We had an experience of IE in prosthetic mitral valve with a moderate size mobile vegetation on ventricular side of prosthesis which was not seenwith different views of TEE due to acoustic shadowing but was visualized during TTE obviously. Really, in Acoustic shadowing phenomena one strong reflector, reflects the ultrasound beam so structures in far field of the

Keywords: tee; prosthetic valve; vegetation; mitral valve; tte; valve

Journal Title: Indian Heart Journal
Year Published: 2017

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.