LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Effect of vent size on vented hydrogen-air explosion

Photo from wikipedia

Abstract In this paper, the effect of vent size on vented hydrogen-air explosion in the room was studied by numerical simulation. Analysis of the explosion temperature, overpressure, dynamic pressure and… Click to show full abstract

Abstract In this paper, the effect of vent size on vented hydrogen-air explosion in the room was studied by numerical simulation. Analysis of the explosion temperature, overpressure, dynamic pressure and wind velocity under different vent sizes indicate that these explosion parameters have different change rules inside and outside the room. Inside the room, the vent size has little effect on the explosion temperature, dynamic pressure and wind velocity, but it has a significant impact on the explosion overpressure. As the scaled vent size K v ( A v / V 2 / 3 ) increases from 0.1 to 0.3, the difference between the maximum internal peak overpressure is 87.8%. Outside the room, as the vent size increases, the high-temperature range (above 800 K) first decreases and then increases, while the explosion dynamic pressure and hurricane zone caused by explosion wind gradually decrease. The maximum high-temperature range (32.5 m for K v  = 0.1) and hurricane zone (41.1 m for K v  = 0.1) can reach 7.0 times and 8.9 times the length of the room, respectively. The explosion dynamic pressure can reach the same order of magnitude as the explosion overpressure under the same vent size. Therefore, these damage effects outside the room cannot be ignored. During the change of vent sizes, for K v  ≤ 0.3, the explosion parameters change drastically and the disaster effect is significant. For example, external explosion that affect the discharge of internal explosion overpressure occur; explosion that occurs in masonry structures can destroy the structural integrity of the brick walls. Therefore, K v  = 0.3 can be used as a reference for hydrogen-air venting safety design.

Keywords: hydrogen; vent size; effect; vent; explosion

Journal Title: International Journal of Hydrogen Energy
Year Published: 2018

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended