Purpose Infection with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) causes COVID-19, a worldwide spreading disease with acute respiratory distress syndrome as one of the major complications. In the early… Click to show full abstract
Purpose Infection with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) causes COVID-19, a worldwide spreading disease with acute respiratory distress syndrome as one of the major complications. In the early disease stage, COVID-19 cannot be distinguished from influenza based on the clinical symptoms. During viraemia, direct pathogen detection by reverse transcription polymerase chain reaction (RT-PCR) is the diagnostic gold standard. This study evaluated a novel real-time RT-PCR test for fast detection and differentiation of RNA from SARS-CoV-2 and influenza virus types A and B. Methods & Materials The assays´ diagnostic performance was compared to CE-IVD/FDA-EUA-marked reference PCR tests. RNA was extracted from patient samples collected as nasopharyngeal or oropharyngeal swabs. Virus-specific RNA was amplified after reverse transcription using the EURORealTime SARS-CoV-2/Influenza A/B PCR test (EUROIMMUN) allowing simultaneous detection of two target sequences in the SARS-CoV-2 ORF1ab and N genes as well as one target sequence each for influenza virus A and B. Assays were carried out on the CFX96 cycler (Bio-Rad) and evaluated with the EURORealTime Analysis Software (EUROIMMUN). The 95% limit of detection (LoD) was determined by Probit analysis using a dilution series of quantified target RNA. To exclude cross-reactivity and interference, the assay was run against human genomic DNA/RNA, nucleic acids from different viral, bacterial and fungal pathogens, and potentially interfering substances. Results Compared to the reference PCR tests, the EURORealTime SARS-CoV-2/Influenza A/B showed positive agreements of 97.8%, 93.0% and 100% and negative agreements of 100%, 100% and 98.9% for SARS-CoV-2, influenza A and influenza B, respectively. The 95% LoD values were calculated to be 0.55cp/µl for SARS-CoV-2, 0.92cp/µl for influenza A H3N2, 0.67cp/µl for influenza A H1N1 and 1.21cp/µl for influenza B. No cross-reactivities with human or pathogen-specific nucleic acids or interferences were detected. Conclusion The novel test is able to detect SARS-CoV-2, influenza A and influenza B with high sensitivity and clearly discriminate between these viruses. It is therefore optimally suited for differential diagnostics for patients presenting with symptoms compatible with COVID-19 and influenza. Combined detection of the three pathogens in one multiparameter assay helps to save time and resources in the diagnostic workup.
               
Click one of the above tabs to view related content.