BACKGROUND Peripheral intravenous catheters are an essential medical device which are prone to complications and failure. OBJECTIVES Identify patient, provider and device risk factors associated with all-cause peripheral intravenous catheter… Click to show full abstract
BACKGROUND Peripheral intravenous catheters are an essential medical device which are prone to complications and failure. OBJECTIVES Identify patient, provider and device risk factors associated with all-cause peripheral intravenous catheter failure as well as individual complications: phlebitis, infiltration/occlusion, and dislodgement to improve patient outcomes. DESIGN Secondary analysis of twelve prospective studies performed between 2008 and 2020. SETTINGS Australian metropolitan and regional hospitals including one paediatric hospital. PARTICIPANTS Participants were from medical, surgical, haematology, and oncology units. METHODS Multilevel mixed-effects parametric survival regression was used to identify factors associated with all-cause peripheral intravenous catheter failure, phlebitis, occlusion/infiltration, and dislodgement. We studied patient (e.g., age, gender), device (e.g., gauge), and provider (e.g., inserting clinician) variables. Stepwise regression involved clinically and p<0.20 significant variables entered into the multivariable model. Results were expressed as hazard ratios (HRs) and 95% confidence intervals (CI); p<0.01 was considered statistically significant. RESULTS Of 11,830 peripheral intravenous catheters (8,200 participants) failure occurred in 36% (n = 4,263). Occlusion/infiltration incidence was 23% (n = 2,767), phlebitis 12% (n = 1,421), and dislodgement 7% (n = 779) of catheters. Patient factors significantly associated with failure and complications were: female gender (phlebitis; (HR 1.98, 95% CI 1.72-2.27), (infiltration/occlusion; HR 1.45, 95% CI 1.33-1.58), (failure; HR 1.36, 95% CI 1.26-1.46); and each year increase in age (phlebitis; 0.99 HR, 95% CI 0.98-0.99), (failure; 0.99 HR, 95% CI 0.99-0.99). The strongest provider risk factor was intravenous antibiotics (infiltration/occlusion; HR 1.40, 95% CI 1.27-1.53), (phlebitis; HR 1.36, 95% CI 1.18-1.56), (failure; HR 1.26, 95% CI 1.17-1.36). Catheters inserted by vascular access teams were less likely to dislodge (HR 0.53, 95% CI 0.42-0.67). Device risk factors most associated with all-cause failure were wrist/hand (HR 1.34, 95% CI 1.23-1.46), antecubital fossa peripheral intravenous catheters (HR 1.29, 95% CI 1.16-1.44) and 22/24 gauge (HR 1.27, 95% CI 1.12-1.45) catheters. CONCLUSION Factors identified, including the protective aspect of vascular access team insertion, and high catheter failure associated with intravenous antibiotic administration, will allow targeted updates of peripheral intravenous catheter guidelines and models of care.
               
Click one of the above tabs to view related content.