LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Performance of non-invasive stroke volume variation during passive leg raising as a predictor of hypotension following induction of spinal anesthesia for elective cesarean delivery: a single cohort study.

Photo by jupp from unsplash

BACKGROUND Spinal anesthesia for cesarean delivery is accompanied by hypotension in up to 70% of cases. To date, there is no gold standard for predicting hypotension after spinal anesthesia for… Click to show full abstract

BACKGROUND Spinal anesthesia for cesarean delivery is accompanied by hypotension in up to 70% of cases. To date, there is no gold standard for predicting hypotension after spinal anesthesia for cesarean delivery. The Clearsight™ device is a non-invasive system that uses a digital cuff to calculate stroke volume. We hypothesized that stroke volume variation induced with passive leg raising before spinal anesthesia for elective cesarean delivery could predict the occurrence of hypotension. METHODS We conducted a prospective observational study, including third trimester parturients undergoing elective cesarean delivery with spinal anesthesia. We analyzed the stroke volume variation performance for predicting hypotension. Stroke volume was collected in the semi-recumbent position (baseline) and during passive leg raising before spinal anesthesia. Systolic arterial blood pressure measurement was followed for 15 min after spinal anesthesia. Hypotension was defined as a ≥20% decrease from the baseline measurement. All parturients received appropriate hypotension prophylaxis. RESULTS Data from 42 parturients were analyzed. Hypotension occurred in 45%. The area-under-the curve for predicting hypotension using the stroke volume variation was 0.83 (95% CI 0.68 to 0.98; P=0.001). The best cut-off value for predicting hypotension was 7%, having a sensitivity of 87% (95% CI 0.70 to 0.99) and a specificity of 83% (95% CI 0.69 to 0.97). CONCLUSION In our study of third trimester parturients undergoing cesarean delivery and receiving appropriate hypotension prophylaxis, a digital non-invasive monitoring device of stroke volume variation analysis was useful for predicting the occurrence of hypotension after spinal anesthesia.

Keywords: spinal anesthesia; stroke volume; cesarean delivery; hypotension

Journal Title: International journal of obstetric anesthesia
Year Published: 2021

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.