Reliability of optical devices for three-dimensional facial anatomy description: a systematic review and meta-analysis.

Photo from wikipedia

The use of three-dimensional (3D) optical instruments to measure soft tissue facial characteristics is increasing, but systematic assessments of their reliability, practical use in research and clinics, outcome measurements, and… Click to show full abstract

The use of three-dimensional (3D) optical instruments to measure soft tissue facial characteristics is increasing, but systematic assessments of their reliability, practical use in research and clinics, outcome measurements, and advantages and limitations are not fully established. Therefore, a review of the current literature was performed on the reliability of facial anthropometric measurements obtained by 3D optical facial reproductions as compared to conventional anthropometry or other optical devices. The systematic literature search was conducted in electronic databases following the PRISMA guidelines (PROSPERO registration: CRD42018085473). Overall, 815 studies were identified, with 27 final papers included. Two meta-analyses were conducted. Tested devices included conventional cameras, laser scanning, stereophotogrammetry, and structured light. Studies measured living people or inanimate objects. Overall, the optical devices were considered reliable for the measurement of linear distances. Some caution is needed for surface assessments. All instruments are suitable for the analysis of inanimate objects, but fast scan devices should be preferred for living subjects to avoid motion artefacts in the orbital and nasolabial areas. Prior facial landmarking is suggested to improve measurement accuracy. Practical needs and economic means should direct the choice of the most appropriate instrument. Considering the increasing interest in surface-to-surface measurements, fast scan devices should be preferred, and dedicated protocols devised.

Keywords: three dimensional; optical devices; analysis; anatomy; meta; reliability

Journal Title: International journal of oral and maxillofacial surgery
Year Published: 2019

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.